Laboratory (LIS)

A laboratory that receives orders and returns results, without retyping.

MedOne's laboratory module is a complete LIS (laboratory information system): requests, sample collection, analyzer work, validation and release, in the same record the doctor uses. It also runs on its own as the LIS of an independent laboratory.

MedOne
MO
Laboratory worklist
24-118
To collect 12Received 9In progress 14To validate 6Released 211
SamplePatientTestPriorityStatus
24-118Ahmed KareemCBC · CRPSTATTo validate
24-117Omar HassanK⁺ · Na⁺ · CreatSTATTo validate
24-116Sara JalalHbA1cRoutineIn progress
24-115Bakhtiyar MahmoodTroponin ISTATIn progress
24-114Maryam YousifTSH · FT4RoutineReceived
24-113Zhyar KamalLipid profileRoutineReleased
CBC · CRP — Ahmed Kareem
Received from analyzer
ResultReferenceFlag
WBC12.44.0–11.0H
Hb13.212.0–15.5—
PLT245150–400—
NEUT %7840–75H
CRP48< 5H
Validate & release
Analyzers
Haematology analyzerConnected
Chemistry analyzerConnected
Immunoassay analyzerIdle
The problem

Handwritten requests get misread, samples get mislabelled, and results are typed twice: once from the analyzer, once into a report. Doctors call the lab to ask if results are ready.

How it works in MedOne
  1. 1Doctor orders the test
  2. 2Sample collected and barcoded
  3. 3Sample received in the lab
  4. 4Analyzer runs the test
  5. 5Result returns to MedOne
  6. 6Lab validates and releases
  7. 7Doctor and patient see the result
Key capabilities

From order to validated result, with barcodes and analyzer links.

01Electronic requests

Orders arrive from doctors, emergency and wards, with priority.

02Barcode samples

Labels printed at collection; each tube tracked by barcode.

03Sample tracking

Collected, received, in progress, completed, released.

04Analyzer integration

ASTM and HL7 links to compatible analyzers, uni- or bidirectional.

05Validation

Technical and medical validation before release.

06Reference ranges & flags

High, low and critical values highlighted automatically.

07Critical value alerts

Critical results flagged to the ordering doctor.

08Result history

Previous values beside today's, for every test.

Who uses it
  • Lab technicians
  • Pathologists
  • Phlebotomy
  • Doctors
  • Patients
Devices & systems
  • Haematology, chemistry and immunoassay analyzers (compatible models)
  • Barcode label printers
  • External reference labs (HL7)

What changes for the hospital

No double entry

Interfaced analyzers send results straight to the sample.

Fewer labelling errors

Barcodes link every tube to the right patient.

Faster turnaround

Doctors see validated results the moment they're released.

See MedOne running a hospital day.

We'll walk your team from registration to discharge using your departments and workflows, in Arabic, Kurdish or English.

Request a demo